Core Needle Biopsy

Contents

Critical

Specimen Requirements

Specimen Storage Requirements

Gauge Size & Quantity Guide

Core Size # of Cores Comment
G14
6 – 8
G16
10 – 12
G18
13 – 15
If G16 is not available
G20+
–
Smaller will usually not yield enough cells.

Core Needle Biopsy Guidance

    • Strands should be around 2cm.
    • Strands in a bad condition do not count towards the total.
    • The cores should be promptly placed into the sample collection tube, ideally within 15 minutes. 
    • If immediate transfer is not possible, place the tissue in sterile saline-moistened gauze (do not submerge in saline) to maintain integrity until transfer.
    • A good quality specimen usually sinks to the bottom of the collection tube.
    • Some doctors have mentioned they in some cases take the cores not from the middle but more to the side of the tumor mass to avoid necrotic tissue.
    • Always try to get as much tissue as is possible.

KYAN's Sample Collection Kit

KYAN's Sample Collection Kit

Collection Tube Handling

Label Tube with Name & DoB

Wrap tube with parafilm tape

Place tube in biohazard bag

Store specimen at 2-8°C until pick up

Specimen Quality Guide

Specimen with sufficient yield & good viability

A large gauge is preferred, 5 large G14 cores lead to sufficient cells.

Many smaller cores of the correct consistency can yield enough cells

Specimen with insufficient yield & low viability

Good consistency but not enough cores

Core Needle Biopsy after Tissue placed in Saline

Tissue was placed in saline solution and was not viable after.

Yellowish fatty or white fibrous tissue will not yield viable cells 

Avoid tissue that contains a lot of blood.

Practice aseptic technique when handling specimen to prevent contamination

Specimen Pick-up Planning

Reach out to our local representative in your country or get in touch via the below contact form to plan sample pick up well ahead of the procedure.

Patient Consent Form

Download the Patient Consent Form and make sure it is fully filled and signed by the patient and a doctor.

The form can be submitted with the specimen. 

Disclaimer
The information on this page supports the KYAN Optim.AI™ testing workflow. Specimen requirements may vary by protocol and jurisdiction, and must be confirmed prior to collection. This information is provided to ensure that samples are collected and transported in a controlled manner, with appropriate chain-of-custody and logistics controls, to support reliable assay performance. If there is any uncertainty, please contact KYAN before submitting samples.

For any sample Collection questions, contact us Now.

    Blue Background Pill Dots